JMS SingleConnectionFactory uses minimized number of start calls (for Oracle AQ; SPR-5987)

master
Juergen Hoeller 15 years ago
parent 6b824d9af7
commit 83bd56c6de
  1. 6
      org.springframework.jms/src/main/java/org/springframework/jms/connection/SingleConnectionFactory.java

@ -510,8 +510,10 @@ public class SingleConnectionFactory
else if (method.getName().equals("start")) {
// Handle start method: track started state.
synchronized (connectionMonitor) {
this.target.start();
started = true;
if (!started) {
this.target.start();
started = true;
}
}
return null;
}