Fixed ConnectionSpecConnectionFactoryAdapter explanation

Issue: SPR-9466
master
Juergen Hoeller 12 years ago
parent 8a12b9e23f
commit cd2183f9e1
  1. 6
      src/reference/docbook/cci.xml

@ -169,9 +169,9 @@
allows for specifying a <interfacename>ConnectionSpec</interfacename>
instance to use for all operations on a given factory. If the adapter's
<literal>connectionSpec</literal> property is specified, the adapter
uses the <literal>getConnection</literal> variant without argument, else
the one with the <interfacename>ConnectionSpec</interfacename>
argument.</para>
uses the <literal>getConnection</literal> variant with the
<interfacename>ConnectionSpec</interfacename> argument, otherwise
the variant without argument.</para>
<programlisting language="xml">&lt;bean id="managedConnectionFactory"